BAL is the bushfire scale. A Group number rates how a wall or ceiling lining behaves in a room fire. The NCC is the building code both sit under. Our Anti-Flam panels are BAL 40 rated with certificates and use Group 1 rated material. A rating always belongs to the tested product, so ask for the certificate.
- Anti-Flam rating
- BAL 40, with certificates
- Material
- Group 1 rated, 38 kg/m³
- Thickness
- 50 and 75 mm
- Price
- From $168 a panel
What BAL means
BAL stands for Bushfire Attack Level. It measures how much radiant heat, ember attack and flame a building is likely to face in a bushfire. The Australian Standard AS 3959 sets six levels.
| Level | Radiant heat on the building | In plain words |
|---|---|---|
| BAL LOW | Very low | Not enough risk to need special construction |
| BAL 12.5 | Up to 12.5 kW/m² | Ember attack |
| BAL 19 | 12.5 to 19 kW/m² | More embers, some burning debris |
| BAL 29 | 19 to 29 kW/m² | Heavier ember attack and more heat |
| BAL 40 | 29 to 40 kW/m² | Heavy ember attack, flames may touch the building |
| BAL FZ | Above 40 kW/m² | The flame zone: direct flame contact |
BAL 40 is the second highest level. At BAL 40 a building can face radiant heat of 29 to 40 kilowatts on every square metre, heavy ember attack, and flames that may touch it at times.
Who decides the BAL for a site
A site gets its BAL from an assessment under AS 3959, which looks at the vegetation around it, the distance to that vegetation and the slope of the land. In Victoria the assessment can be done by a building surveyor, an architect, a designer, a builder or the owner, and a home in a bushfire prone area is built to at least BAL 12.5.
Your building surveyor confirms the level your job has to meet.
What a Group number means
Inside a building, the NCC rates wall and ceiling linings from Group 1 to Group 4 by how they behave in a room fire test. The test burns a gas burner in the corner of a lined room and watches for flashover, the moment the whole room catches.
| Group | What happened in the room fire test |
|---|---|
| Group 1 | No flashover through the whole 20 minute test |
| Group 2 | Flashover in the second half of the test, at the higher burner setting |
| Group 3 | Flashover between 2 and 10 minutes |
| Group 4 | Flashover within 2 minutes |
Group 1 is the best result. The NCC asks for Group 1 in the most sensitive parts of a building, such as fire isolated exits.
Where the NCC fits
The NCC is the National Construction Code. It sets the fire, structural and energy rules for buildings across Australia, and both BAL levels and Group numbers are used through it. Victoria adopted the 2025 edition on 1 May 2026.
BPAU insulated panel systems meet Australian NCC building standards.
What our Anti-Flam panels are rated to
Our Anti-Flam panels are made for higher risk jobs. They are BAL 40 rated with certificates, and they use Group 1 rated material with a high density 38 kg/m³ core. They meet Australian commercial fire safety requirements and are tested for the Australian market.
Anti-Flam wall panels come in 50 and 75 mm, from $168 a panel. Thicker panels are available on request.

A rating depends on how the panel is used
A fire rating comes from a test of one product, at one thickness, built one way. It holds when the panel is installed the way it was tested.
Insurers and the panel industry stress the same basics on site: keep the core covered at edges and openings, seal holes for pipes and cables properly, and keep welding and grinding well away from panels.
What to ask before you buy
Ask for the test certificate, not only the rating. Check that the certificate names the product and the thickness you are buying. And ask your building surveyor which BAL and which Group number your job needs before you order.
We supply data sheets and certificates with your quote. Call 1800 377 726 or ask for them here.
Products in this guide




- CSIRO: Bushfire Attack Level assessment
- CFA Victoria: glossary of bushfire planning terms
- Hepburn Shire Council: bushfire prone areas
- National Construction Code 2022, Specification 7: fire hazard properties
- Jensen Hughes: fire hazard properties of wall and ceiling linings
- HIA: NCC 2025 adopted in Victoria, 1 May 2026
- Insulated Panel Council Australasia: about panel
- Vero Insurance: EPS sandwich panels, hazards and controls
Facts about BPAU panels come from our own data sheets and certificates, which we supply on request.